ModvBox

MODULAR MULTIZONE DISTRIBUTION BOX FOR GAS WALL-HUNG BOILERS AND HEAT PUMPS

Modular multi-zone distribution box for wall-hung gas boilers and heat pumps. Its extremely compact design makes it possible to hydraulically connect up to three circuits within just 450 mm of usable width.
The primary circuit to the boiler or heat pump includes 2 1” male shut-off valves and a distribution manifold with integrated hydraulic separator or a simple manifold, for outputs up to 50 kW. The hydraulic separator allows the primary circuit to be hydraulically decoupled from the secondary circuit and permits greater volumetric flow of the heat-transfer fluid in the user circuits than what circulates in the boiler or heat pump. In gas boiler installations, the return temperature to the boiler is reduced, thus ensuring improved system efficiency. Air vent valve and deaeration chamber. IP55 junction box to facilitate electrical wiring. The distribution box, powder-coated in RAL 9010 white, can be installed on the wall, recessed, or inside a suspended cabinet.

Main features
Maximum flow rate in the primary circuit up to 2 m³/h;
Primary circuit connections: 1” male; center distance 270 mm;
Dimensions: (WxDxH) 450x160x550 mm;
Internal insulation in PPE (where предусмотрed);
Maximum power: 50 kW - Max. 6 bar;
Pressure drop of hydraulic separator: 0.2 mH2O at a flow rate of 2000 l/h;
Pressure drop of manifold: 0.3 mH2O at a flow rate of 1500 l/h on each circuit.

The modular system allows you to choose from three types of pumping groups:

Direct
Motorized mixing
Fixed-point mixing

The pumping groups, with 70 mm center distance and 3/4” female user connection, can be connected to the manifold as desired, by number and position among those available, thus building a configuration that is always suitable for the application. Each zone is supplied with a Wilo Para 15-130/6 SC circulator (other head ratings available on request). In addition to the circulator, each pumping group is equipped with DN 20 shut-off valve for both supply and return, 0°÷120°C thermometer, and a non-return valve that can be excluded during system maintenance. Each valve has a probe well should the boiler electronics require it.